The AER Auto is an advanced system that digitally monitors the patients weight distribution and adapts pressure in the cells accordingly. This intelligent air mattress also provides extra comfort with two therapy modes alternating and constant low pressure (CLP).
Using the latest Intelligent Smart Sensor (ISS), the AER Auto pump will adjust cell pressure by precisely calibrating the current weight and patient position without manual intervention.
Added to this heel and prone zone cells can be removed to achieve zero pressure and enable nursing in prone position.
A fantastic all round system offering outstanding relief for medium to very high risk patients, grade 3 -4.
Key Features
Fully Automatic
Auto-weigh, auto adjust alternating pressure relieving mattress.
Intelligent Smart Sensor
Intelligent smart sensor that continuously monitors patient's movements and adjusts pressure in cells accordingly.
Square Cells
Square cells for greater comfort, enhanced pressure relief and maximum pressure distribution.
Cell on Cell
Advanced cell on cell technology reduces the risk of the mattress bottoming out.
Heel and Prone Zone
Air cells can be removed to achieve zero pressure on heels and for nursing in prone position.
One Pump Three Mattresses
Pumps can operate on three different depth mattresses; overlay, mattress replacement and 7" and 8" full replacement.
- Multiple size depths to provide care and pressure relief for all category stages of pressure ulcer prevention and treatment
- Full replacement 7" (18cm). Low - very high risk
- Full Replacement 8" (20cm). Low – very high risk
- A total of twenty square air cells, three head end cells are static
- Cell on cell technology with the sub cell remaining inflated at all times to reduce the risk of the patient bottoming out
- Cell on cell technology provides reliability in the event of a power failure as the mattress has a sub supportive surface
- Heel protect zone; air cell can be removed without disturbing the patient to achieve zero pressure as required
- Prone zone; removal of air cells from the head area allows the patient to be nursed in a prone position
- Alternation therapy mode on a 1 in 2 cell cycle, three cells at the head end are static. Default cycle time between A & B cells is 10 minutes
- Time to inflate on initial use is approximately 20 minutes
- Four-way multi-stretch polyurethane (PU) cover to reduce shear and friction
- Fully welded, vapour permeable, water resistant cover with 360 degree concealed zipper for easy removal with PU overhang to stop ingress of fluids
- BS7175 Crib 5 flame retardant cover
- Turn CPR for rapid deflation in case of an emergency and prevents accidental deflation
- Transport mode feature, mattress will stay inflated for up to 12hrs
- AER Auto operates with the AER MR, a Foam Mattress Replacement 5” round cells + 2” foam (18cm). Low – high risk.
- AER Auto automatically adjusts internal mattress pressure without manual intervention.
- Alternating therapy is the default mode for the AER Auto pump, continuously over a period of time inflating and deflating air cells to relieve pressure away from vulnerable areas, whilst stimulating blood flow circulation across the entire body.
- Constant Low Pressure (CLP) therapy can be used as an alternative to alternating mode. CLP button must be pressed to activate, equalising pressure throughout all the cells to provide greater immersion, optimum pressure distribution and constant low interface pressure across the mattress surface.
- Comfort setting has been developed for comfort only. The AER Auto will adjust the internal pressures and set the comfort mode automatically. If the patient requires a softer or firmer mattress, the clinician can alter the comfort mode to the desired setting.
- Adjustable cycle times allows clinicians to customise the alternation therapy delivered to the patient, which can support a step down process.
- Max inflate, mattress to inflate quickly to its maximum support surface to aid nursing procedures such as repositioning and patient transfers. Max Inflate will be active for 20 minutes, after 20 minutes the pump will revert to its last therapy mode.
- Seat boost mode adjusts the mattress pressures to provide continuous support when the bed is profiled in a seating position. Optimising support on the sacrum area where 75% of the patients’ weight will be insitu, reducing the risk of ‘bottoming out’.
- Unlock feature, the panel will lock out after one minute if buttons are not being activated. Touch unlock button for 3 seconds and the pump will unlock, activating all therapy modes. This feature decreases the risk of people tampering with the pump’s settings.
- Mute button, to mute alarms for low pressure or power shortage. If the problem is not resolved, the pump will re-alarm. The pump will continue to do this process until the issue is fixed.
- Multiple audible and visual alarms warning of low pressure, alternation failure and power failure.
Instruction Manual - Click Here